AB - Background: Surgical training is undergoing major changes with reduced resident work hours and an increasing focus on patient safety and surgical aptitude. The aim of this study was to create a valid, reliable method for an assessment of arthroscopic skills that is independent of time and place and is designed for both real and simulated settings. The validity of the scale was tested using a virtual reality shoulder arthroscopy simulator.Methods: The study consisted of two parts. In the first part, an Imperial Global Arthroscopy Rating Scale for assessing technical performance was developed using a Delphi method. Application of this scale required installing a dual-camera system to synchronously record the simulator screen and body movements of trainees to allow an assessment that is independent of time and place. The scale includes aspects such as efficient portal positioning, angles of instrument insertion, proficiency in handling the arthroscope and adequately manipulating the camera, and triangulation skills. In the second part of the study, a validation study was conducted. Two experienced arthroscopic surgeons, blinded to the identities and experience of the participants, each assessed forty-nine subjects performing three different tests using the Imperial Global Arthroscopy Rating Scale. Results were analyzed using two-way analysis of variance with measures of absolute agreement. The intraclass correlation coefficient was calculated for each test to assess inter-rater reliability.Results: The scale demonstrated high internal consistency (Cronbach alpha, 0.918). The intraclass correlation coefficient demonstrated high agreement between the assessors: 0.91 (p < 0.001). Construct validity was evaluated using Kruskal-Wallis one-way analysis of variance (chi-square test, 29.826; p < 0.001), demonstrating that the Imperial Global Arthroscopy Rating Scale distinguishes significantly between subjects with different levels of experience utilizing a virtual reali
AU - Bayona,S
AU - Akhtar,K
AU - Gupte,C
AU - Emery,RJH
AU - Dodds,AL
AU - Bello,F
DO - 10.2106/JBJS.M.00304
PY - 2014///
SN - 0021-9355
TI - Assessing performance in shoulder arthroscopy: The Imperial Global Arthroscopy Rating Scale (IGARS)
T2 - Journal of Bone and Joint Surgery: American Volume
UR - http://dx.doi.org/10.2106/JBJS.M.00304
UR - http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000343798700007&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
UR - https://journals.lww.com/jbjsjournal/Abstract/2014/07020/Assessing_Performance_in_Shoulder_Arthroscopy__The.18.aspx
VL - 96A
ER -
Department of Surgery and CancerCentre for Engagement and Simulation ScienceVisit our YouTube channel

General Enquiries


For further information on our research projects or current opportunities, please contact:

Professor of Surgical Computing and Simulation Science
Professor Fernando Bello

f.bello@imperial.ac.uk
+44 (0)20 3315 8231