Main content blocks

Head of Group

Prof Ferdinando Rodriguez y Baena

B415C Bessemer Building

South Kensington Campus

 

About us

The MIM Lab develops robotic and mechatronics surgical systems for a variety of procedures.

Research lab info

What we do

The Mechatronics in Medicine Laboratory develops robotic and mechatronics surgical systems for a variety of procedures including neuro, cardiovascular, orthopaedic surgeries, and colonoscopies. Examples include bio-inspired catheters that can navigate along complex paths within the brain (such as EDEN2020), soft robots to explore endoluminal anatomies (such as the colon), and virtual reality solutions to support surgeons during knee replacement surgeries.

Why it is important?

...

How can it benefit patients?

......

Meet the team

No results found

Search or filter publications

Filter by type:

Filter by publication type

Filter by year:

to

Results

  • Showing results for:
  • Reset all filters

Search results

  • Journal article
    Di Ieva A, Grizzi F, Rognone E, Tse ZTH, Parittotokkaporn T, Rodriguez y Baena F, Tschabitscher M, Matula C, Trattnig S, Rodriguez y Baena Ret al., 2010,

    Magnetic resonance elastography: a general overview of its current and future applications in brain imaging

    , Neurosurg Rev, Vol: 33, Pages: 137-145, ISSN: 0344-5607

    Magnetic resonance elastography (MRE) has been developed over the last few years as a non-invasive means of evaluating the elasticity of biological tissues. The presence of the skull has always prevented semeiotic palpation of the brain, but MRE now offers the possibility of "palpating by imaging" in order to detect brain consistency under physiological and pathological conditions. The aim of this article is to review the current state-of-the-art of MRE imaging and discuss its possible future diagnostic applications in neuroscience.

  • Journal article
    Brett PN, Rodriguez y Baena F, 2010,

    Special issue on microtechnologies for surgery

    , Vol: 224, Pages: i-ii, ISSN: 0954-4119
  • Conference paper
    Frasson L, Neubert J, Reina S, Oldfield M, Davies BL, Rodriguez y Baena Fet al., 2010,

    Development and Validation of a Numerical Model for Cross-section Optimization of a Multi-Part Probe for Soft Tissue Intervention

    , 32nd Annual International Conference of the IEEE Engineering-in-Medicine-and-Biology-Society (EMBC 10), Publisher: IEEE, Pages: 3202-3205, ISSN: 1557-170X
  • Conference paper
    Ko SY, Davies BL, Rodriguez y Baena F, 2010,

    Two-Dimensional Needle Steering with a "Programmable Bevel" Inspired by Nature: Modeling Preliminaries

    , IEEE/RSJ International Conference on Intelligent Robots and Systems, Publisher: IEEE, Pages: 2319-2324, ISSN: 2153-0858
  • Journal article
    Rodriguez y Baena F, Davies B, 2010,

    Robotic surgery: from autonomous systems to intelligent tools

    , Robotica, Vol: 28, Pages: 163-170, ISSN: 0263-5747

    A brief history of robotic surgery is provided, which describes the transition from autonomous robots to hands-on systems that are under the direct control of the surgeon. An example of the latter is the Acrobot (for active-constraint robot) system used in orthopaedics, whilst soft-tissue Surgery is illustrated by the daVinci telemanipulator system. Non-technological aspects of robotic surgery have often been a major impediment to their widespread clinical use. These are discussed in detail, together with the role of navigation systems, which are considered a major competitor to Surgical robots. A detailed description is then given of a registration method for robots to achieve improved accuracy. Registration is a major source of error in robotic surgery, particularly in orthopaedics. The paper describes the design and clinical implementation of a novel method, coined the bounded registration method, applied to minimally invasive registration of the femur. Results of simulations which compare the performance of bounded registration with a standard implementation of the iterative closest point algorithm are also presented, alongside a description of their application in the Acrobot hands-on robot, used clinically for uni-condylar knee arthroplasty.

  • Conference paper
    Oldfield M, Dini D, Rodriguez y Baena F, 2010,

    Detailed Finite Element Simulations of Probe Insertion into Solid Elastic Material using a Cohesive Zone Approach

    , 32nd Annual International Conference of the IEEE Engineering-in-Medicine-and-Biology-Society (EMBC 10), Publisher: IEEE, Pages: 3198-3201, ISSN: 1557-170X
  • Journal article
    Iranpour F, Merican AM, Rodriguez y Baena F, Cobb JP, Amis AAet al., 2010,

    Patellofemoral Joint Kinematics: The Circular Path of the Patella around the Trochlear Axis

    , J Orthop Res, Vol: 28, Pages: 589-594, ISSN: 0736-0266

    Differing descriptions of patellar motion relative to the femur have resulted from previous studies. We hypothesized that patellar kinematics would correlate to the trochlear geometry and that differing descriptions could be reconciled by accounting for differing alignments of measurement axes. Seven normal fresh-frozen knees were CT scanned, and their kinematics with quadriceps loading was measured by an optical tracker system. Kinematics was calculated in relation to the femoral epicondylar, anatomic, and mechanical axes. A novel trochlear axis was defined, between the centers of spheres best fitted to the medial and lateral trochlear articular surfaces. The path of the center of the patella was circular and uniplanar (root-mean-square error 0.3 mm) above 16 +/- 3 degrees (mean +/- SD) knee flexion. In the coronal plane, this circle was aligned 6 +/- 2 degrees from the femoral anatomical axis, close to the mechanical axis alignment. It was 91 +/- 3 degrees from the epicondylar axis, and 88 +/- 3 degrees from the trochlear axis. In the transverse plane it was 91 +/- 3 degrees and 88 +/- 3 degrees from the epicondylar and trochlear axes, respectively. Manipulation of the data to different axis alignments showed that differing previously published data could be reconciled. The circular path of patellar motion around the trochlea, aligned with the mechanical axis of the leg, is easily visualized and understood. (C) 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:589-594, 2010

  • Conference paper
    Tenzer Y, Davies BL, Rodriguez y Baena F, 2010,

    Programmable differential brake for passive haptics

    , Robotics and Autonomous Systems, Pages: 249-255, ISSN: 0921-8890

    This paper outlines work on a novel programmable braking system, which is widely applicable to most passive haptic applications and benefits from a simple design, theoretically infinite positional resolution and the ability to generate stiff collision forces, without the need for any explicit force measurements. Results are also given of a preliminary concept demonstrator which is based on a simple 2-Degrees-Of-Freedom (DOF) Revolute-Revolute (RR) manipulator incorporating the programmable brakes. Performance measures for the joint, as well as figures describing the ability of the 2-DOF prototype to constrain the end effector motion to a plane and a circle. are also provided. (C) 2009 Elsevier B.V. All rights reserved.

  • Conference paper
    Frasson L, Reina S, Davies BL, Rodriguez y Baena Fet al., 2009,

    Design Optimisation of a Biologically Inspired MultiPart Probe for Soft Tissue Surgery

    , 11th International Congress of the IUPESM/World Congress on Medical Physics and Biomedical Engineering, Publisher: SPRINGER, Pages: 307-310, ISSN: 1680-0737
  • Conference paper
    Schneider A, Frasson L, Parittotokkaporn T, Rodriguez y Baena F, Davies BL, Huq SEet al., 2009,

    Biomimetic microtexturing for neurosurgical probe surfaces to influence tribological characteristics during tissue penetration

    , Microelectronic Engineering, Pages: 1515-1517, ISSN: 0167-9317

This data is extracted from the Web of Science and reproduced under a licence from Thomson Reuters. You may not copy or re-distribute this data in whole or in part without the written consent of the Science business of Thomson Reuters.

Request URL: http://www.imperial.ac.uk:80/respub/WEB-INF/jsp/search-t4-html.jsp Request URI: /respub/WEB-INF/jsp/search-t4-html.jsp Query String: id=1303&limit=10&page=17&respub-action=search.html Current Millis: 1726878331270 Current Time: Sat Sep 21 01:25:31 BST 2024

Contact Us

General enquiries
hamlyn@imperial.ac.uk

Facility enquiries
hamlyn.facility@imperial.ac.uk


The Hamlyn Centre
Bessemer Building
South Kensington Campus
Imperial College
London, SW7 2AZ
Map location