Citation

BibTex format

@article{Singh:2015:10.1016/j.jbiomech.2015.11.040,
author = {Singh, SD and Xu, XY and Wood, NB and Pepper, JR and Izgi, C and Treasure, T and Mohiaddin, RH},
doi = {10.1016/j.jbiomech.2015.11.040},
journal = {Journal of Biomechanics},
pages = {100--111},
title = {Aortic flow patterns before and after personalised external aortic root support implantation in Marfan patients.},
url = {http://dx.doi.org/10.1016/j.jbiomech.2015.11.040},
volume = {49},
year = {2015}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Implantation of a personalised external aortic root support (PEARS) in the Marfan aorta is a new procedure that has emerged recently, but its haemodynamic implication has not been investigated. The objective of this study was to compare the flow characteristics and hemodynamic indices in the aorta before and after insertion of PEARS, using combined cardiovascular magnetic resonance imaging (CMR) and computational fluid dynamics (CFD). Pre- and post-PEARS MR images were acquired from 3 patients and used to build patient-specific models and upstream flow conditions, which were incorporated into the CFD simulations. The results revealed that while the qualitative patterns of the haemodynamics were similar before and after PEARS implantation, the post-PEARS aortas had slightly less disturbed flow at the sinuses, as a result of reduced diameters in the post-PEARS aortic roots. Quantitative differences were observed between the pre- and post-PEARS aortas, in that the mean values of helicity flow index (HFI) varied by -10%, 35% and 20% in post-PEARS aortas of Patients 1, 2 and 3, respectively, but all values were within the range reported for normal aortas. Comparisons with MR measured velocities in the descending aorta of Patient 2 demonstrated that the computational models were able to reproduce the important flow features observed in vivo.
AU - Singh,SD
AU - Xu,XY
AU - Wood,NB
AU - Pepper,JR
AU - Izgi,C
AU - Treasure,T
AU - Mohiaddin,RH
DO - 10.1016/j.jbiomech.2015.11.040
EP - 111
PY - 2015///
SN - 1873-2380
SP - 100
TI - Aortic flow patterns before and after personalised external aortic root support implantation in Marfan patients.
T2 - Journal of Biomechanics
UR - http://dx.doi.org/10.1016/j.jbiomech.2015.11.040
UR - http://hdl.handle.net/10044/1/30622
VL - 49
ER -

Contact us

Room 1M17, ACE Extension Building
Department of Chemical Engineering
Imperial College London, South Kensington Campus
London, SW7 2AZ, UK

Tel: +44 (0)207 594 2562