Results
- Showing results for:
- Reset all filters
Search results
-
Journal articleSun N, Wood NB, Hughes AD, et al., 2007,
Influence of pulsatile flow on LDL transport in the arterial wall
, ANNALS OF BIOMEDICAL ENGINEERING, Vol: 35, Pages: 1782-1790, ISSN: 0090-6964- Author Web Link
- Cite
- Citations: 30
-
Journal articleAugst AD, Ariff B, Thom SAGM, et al., 2007,
Analysis of complex flow and the relationship between blood pressure, wall shear stress, and intima-media thickness in the human carotid artery
, AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, Vol: 293, Pages: H1031-H1037, ISSN: 0363-6135- Author Web Link
- Cite
- Citations: 73
-
Journal articleMa CYJ, Kumar R, Xu XY, et al., 2007,
A combined fluid dynamics, mass transport and cell growth model for a three-dimensional perfused biorector for tissue engineering of haematopoietic cells
, BIOCHEMICAL ENGINEERING JOURNAL, Vol: 35, Pages: 1-11, ISSN: 1369-703X- Author Web Link
- Cite
- Citations: 34
-
Journal articleDownie SP, Firmin DN, Wood NB, et al., 2007,
Role of MRI in investigating the effects of elastic compression stockings on the deformation of the superficial and deep veins in the lower leg
, JOURNAL OF MAGNETIC RESONANCE IMAGING, Vol: 26, Pages: 80-85, ISSN: 1053-1807- Author Web Link
- Cite
- Citations: 20
-
Journal articleSun N, Wood NB, Hughes AD, et al., 2007,
Effects of transmural pressure and wall shear stress on LDL accumulation in the arterial wall: a numerical study using a multilayered model
, AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, Vol: 292, Pages: H3148-H3157, ISSN: 0363-6135- Author Web Link
- Cite
- Citations: 51
-
Book chapterXY Xu, NB Wood, 2007,
The proximal carotid arteries – image-based computational modelling
, Carotid Disease: The Role of Imaging in Diagnosis and Management, Editors: Gillard, Graves, Hatsukami, Yuan, Cambridge, Publisher: Cambridge University Press, Pages: 313-323, ISBN: 9780521862264 -
Conference paperTorii R, Wood NB, Hadjiloizou N, et al., 2007,
Does the difference in realistic waveform before and after stenting affect hemodynamics in stenosed coronary artery?
, ASME Summer Bioengineering Conference, Publisher: AMER SOC MECHANICAL ENGINEERS, Pages: 467-468 -
Journal articleTorii R, Wood NB, Hughes AD, et al., 2007,
A computational study on the influence of catheter-delivered intravascular probes on blood flow in a coronary artery model
, JOURNAL OF BIOMECHANICS, Vol: 40, Pages: 2501-2509, ISSN: 0021-9290- Author Web Link
- Cite
- Citations: 20
-
Conference paperSun N, Torii R, Wood NB, et al., 2007,
Numerical simulation of blood-wall albumin transport in a realistic human right coronary artery
, ASME Summer Bioengineering Conference, Publisher: AMER SOC MECHANICAL ENGINEERS, Pages: 107-108 -
Conference paperBorghi A, Wood NB, Mohiaddin RH, et al., 2007,
Fluid-solid interaction simulation of flow and stress pattern in thoracoabdominal aneurysms: A patient specific study
, 6th Symposium on Fluid-Structure Interactions, Aeroelasticity and Flow-Induced Vibration and Noise, Publisher: AMER SOC MECHANICAL ENGINEERS, Pages: 671-675 -
Journal articleBorghi A, Wood NB, Mohiaddin RH, et al., 2006,
3D geometric reconstruction of thoracic aortic aneurysms
, BIOMEDICAL ENGINEERING ONLINE, Vol: 5, ISSN: 1475-925X- Author Web Link
- Open Access Link
- Cite
- Citations: 15
-
Journal articleWood NB, Zhao SZ, Zambanini A, et al., 2006,
Curvature and tortuosity of the superficial femoral artery: a possible risk factor for peripheral arterial disease
, JOURNAL OF APPLIED PHYSIOLOGY, Vol: 101, Pages: 1412-1418, ISSN: 8750-7587- Author Web Link
- Cite
- Citations: 104
-
Journal articleAriff B, Zambanini A, Vamadeva S, et al., 2006,
Candesartan- and atenolol-based treatments induce different patterns of carotid artery and left ventricular remodeling in hypertension
, STROKE, Vol: 37, Pages: 2381-2384, ISSN: 0039-2499- Author Web Link
- Cite
- Citations: 41
-
Journal articleSun N, Wood NB, Hughes AD, et al., 2006,
Fluid-wall modelling of mass transfer in an axisymmetric stenosis: Effects of shear-dependent transport properties
, ANNALS OF BIOMEDICAL ENGINEERING, Vol: 34, Pages: 1119-1128, ISSN: 0090-6964- Author Web Link
- Cite
- Citations: 81
-
Journal articleLeung JH, Wright AR, Cheshire N, et al., 2006,
Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models
, Biomedical Engineering Online, Vol: 5, ISSN: 1475-925XBackgroundAbdominal aortic aneurysm (AAA) is a dilatation of the aortic wall, which can rupture, if left untreated. Previous work has shown that, maximum diameter is not a reliable determinant of AAA rupture. However, it is currently the most widely accepted indicator. Wall stress may be a better indicator and promising patient specific results from structural models using static pressure, have been published. Since flow and pressure inside AAA are non-uniform, the dynamic interaction between the pulsatile flow and wall may influence the predicted wall stress. The purpose of the present study was to compare static and dynamic wall stress analysis of patient specific AAAs.MethodPatient-specific AAA models were created from CT scans of three patients. Two simulations were performed on each lumen model, fluid structure interaction (FSI) model and static structural (SS) model. The AAA wall was created by dilating the lumen with a uniform 1.5 mm thickness, and was modeled as a non-linear hyperelastic material. Commercial finite element code Adina 8.2 was used for all simulations. The results were compared between the FSI and SS simulations.ResultsResults are presented for the wall stress patterns, wall shear stress patterns, pressure, and velocity fields within the lumen. It is demonstrated that including fluid flow can change local wall stresses slightly. However, as far as the peak wall stress is concerned, this effect is negligible as the difference between SS and FSI models is less than 1%.ConclusionThe results suggest that fully coupled FSI simulation, which requires considerable computational power to run, adds little to rupture risk prediction. This justifies the use of SS models in previous studies.
-
Book chapterWood N B, Xu X Y, 2006,
Modelling of haemodynamics in the cardiovascular system by integrating medical imaging techniques and computer modelling tools.
, Multidisciplinary Approaches to Theory in Medicine., Editors: Paton, McNamara, Paton, McNamara, Amsterdam, The Netherlands, Publisher: Elsevier B V, Pages: 325-351, ISBN: 9780444518064 -
Journal articleMa CYJ, Mantalaris A, Xu XY, 2005,
Development of a mathematical model for a 3-D perfused bone marrow culture system
, AIChE Annual Meeting, Conference Proceedings, Pages: 8808-8818Bone marrow (BM) is a three-dimensional tissue and the site of blood formation. The successful reconstruction of the BM has enormous potential benefits to the society. Its success depends, partly, on the development of a suitable culture system necessary for its growth. In the present work, we have developed a mathematical model for a 3-D perfused BM culture system that captures the growth characteristics of the BM microenvironment, and as a first approximation, mimics the structural entity of in vivo BM. The model has been used to investigate cellular growth, fluid flow, shear stress and nutrient distribution within a Rotating Wall Perfused Bioreactor - RWPB (Synthecon Inc.). Based on our preliminary results, for a 2 week culture, it was observed that the total cell number increased by 30 and 38 fold for a scaffold with 90% and 80% porosity, respectively. Further analysis showed that, with a 20% oxygen supply, the oxygen tension was sufficiently maintained to avoid hypoxic regions, but with increasing axial distance in the bioreactor some areas experienced low oxygen levels; though this effect varied with porosity of the scaffold.
-
Journal articleLeung JH, Wright A, Cheshire N, et al., 2005,
Fluid-structure interaction in patient specific models of the abdominal aortic aneurysm
, Proceedings of the 2005 Summer Bioengineering Conference, Vol: 2005, Pages: 1450-1451 -
Journal articleWood NB, Exarchou I, Xu XY, et al., 2005,
Progress with the study of retinal hemodynamics in normotensive and hypertensive patients
, Proceedings of the 2005 Summer Bioengineering Conference, Vol: 2005, Pages: 259-260- Cite
- Citations: 1
-
Journal articleWood NB, Xu XY, 2005,
18 Modelling of haemodynamics in the cardiovascular system by integrating medical imaging techniques and computer modelling tools
, Studies in Multidisciplinarity, Vol: 3, Pages: 325-351, ISSN: 1571-0831- Cite
- Citations: 2
This data is extracted from the Web of Science and reproduced under a licence from Thomson Reuters. You may not copy or re-distribute this data in whole or in part without the written consent of the Science business of Thomson Reuters.
Contact us
Room 1M17, ACE Extension Building
Department of Chemical Engineering
Imperial College London, South Kensington Campus
London, SW7 2AZ, UK
Tel: +44 (0)207 594 2562