Citation

BibTex format

@article{Torii:2009:10.1002/cnm.1231,
author = {Torii, R and Wood, NB and Hadjiloizou, N and Dowsey, AW and Wright, AR and Hughes, AD and Davies, J and Francis, DP and Mayet, J and Yang, GZ and Thom, SAM and Xu, XY},
doi = {10.1002/cnm.1231},
journal = {Communications in Numerical Methods in Engineering},
pages = {565--580},
title = {Fluid-structure interaction analysis of a patient-specific right coronary artery with physiological velocity and pressure waveforms},
url = {http://dx.doi.org/10.1002/cnm.1231},
volume = {25},
year = {2009}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Coupled fluid-structure interaction (FSI) analysis of the human right coronary artery (RCA) has been carried out to investigate the effects of wall compliance on coronary hemodynamics. A 3-D model of a stenosed RCA was reconstructed based oil multislice computerized tomography images. A velocity waveform in the proximal RCA and a pressure waveform in the distal RCA of a patient with a severe stenosis were acquired with a catheter delivered wire probe and applied as boundary conditions. The arterial wall was modeled as a Mooncy-Rivlin hyperelastic material. The predicted maximum wall displacement (3.85 mm) was comparable with the vessel diameter (similar to 4 mm), but the diameter variation was much smaller, 0.134 mm at the stenosis and 0.486 mm in the distal region. Comparison of the computational results between the FSI and rigid-wall models showed that the instantaneous wall shear stress (WSS) distributions were affected by diameter variation in the arterial walk increasing systolic blood pressure dilated the vessel and consequently lowered WSS, whereas the opposite occurred When pressure started to decrease. However. file effects of wall compliance on time-averaged WSS (TAWSS) and oscillatory shear index (OSI) were insignificant (4.5 and 2.7% difference in maximum TAWSS and OSI. respectively). Copyright (C) 2009 John Wiley & Sons, Ltd.
AU - Torii,R
AU - Wood,NB
AU - Hadjiloizou,N
AU - Dowsey,AW
AU - Wright,AR
AU - Hughes,AD
AU - Davies,J
AU - Francis,DP
AU - Mayet,J
AU - Yang,GZ
AU - Thom,SAM
AU - Xu,XY
DO - 10.1002/cnm.1231
EP - 580
PY - 2009///
SN - 1069-8299
SP - 565
TI - Fluid-structure interaction analysis of a patient-specific right coronary artery with physiological velocity and pressure waveforms
T2 - Communications in Numerical Methods in Engineering
UR - http://dx.doi.org/10.1002/cnm.1231
VL - 25
ER -

Contact us

Room 1M17, ACE Extension Building
Department of Chemical Engineering
Imperial College London, South Kensington Campus
London, SW7 2AZ, UK

Tel: +44 (0)207 594 2562